Configuration summary
| Model | NBWX-1/1 |
|---|---|
| Configuration type | Type B RCD box |
| Voltage class | 400V AC |
| Input count | 1 |
| Output count | 1 |
| Protection / switching architecture | Type B RCD + MCB |
Technical specifications
| Input | 1 string |
|---|---|
| Output | 1 string |
| Maximum Voltage | 400V |
| Max DC Short Circuit Current Per Input (Isc) | 25A(Changeable) |
| Maximum Current Output | 25A |
| Enclosure | BX-08 |
| Material Type | Polycarbonate/ABS |
| Degree of Protection | IP65 |
| Degree of Resistance to Impacts | IK10 |
| Dimension (WxHxD) | 197x210x120mm |
| Cable Input Entry | PG25 Cable Gland,13-21mm² |
| Output Cable Gland | PG25 Cable Gland,13-21mm² |
| Residual current circuit Breaker | NL210 |
| Residual current circuit Breaker Rated Voltage (Ue) | AC 400V/415V |
| Residual current circuit Breaker Rated Current (In) | 25A |
| Residual current circuit Breaker Standard Compliance with | IEC 61008-1 62423,GB/T 16916.1 22794 |
| Residual current circuit Breaker Certification | CE,CCC,KEMA-KEUR |
| Residual current circuit Breaker Rated residual action current | 0.3A |
| Miniature circuit Breaker | NB1-63H/3P B25A |
| Miniature circuit Breaker Rated Voltage (Ue) | 400VAC |
| Miniature circuit Breaker Rated Current (In) | 25A |
| Miniature circuit Breaker Standard Compliance with | IEC 60898-1,GB/T 10963.1 |
| Miniature circuit Breaker Certification | CE,CCC,SEMKO |
| Miniature circuit Breaker Instantaneous trip type | Type B |
| Operating Temperature | -20°C~+60°C |
| Humidity | 99% |
| Altitude | 2000M |
| Installation | Wall Mounting |
Technical context
Use the relevant selection guide before finalizing the scope.
How to Choose a Home Distribution Box: An Engineer's Guide
A buyer's guide to selecting a home distribution box by circuit count, main-switch capacity, protection devices, enclosure material, IP rating and future loads.
Read Insight →Low-voltage systems / Engineering guideACDB Full Form in Electrical: Understanding the AC Distribution Box
ACDB stands for AC Distribution Box — an enclosed low-voltage assembly that receives alternating current from one supply point and distributes it to several protected outgoing circuits. In a solar plant it sits on the inverter output between the inve
Read Insight →